ADVANCED AUTOMATION TECHNOLOGIES

Product Catalog

Cables for Temperature Probes

It's used to connect a temperature probe (RTD, thermocouple and thermistor). There are various insulations for cables to operate in the most extreme environments: high and low temperature, aggressive environment, bending, mobility, etc. Single and multi-layer PVC insulation, organosilicon rubber (silicone), PFA and MFA teflon, fiberglass, ceramic fiber, stainless steel and high temperature alloys, unshielded and shielded by foil, tin copper or stainless braid, monocore and multicore, different sections and diameters.

The full assortment of cables to connect thermocouples of all existing types, including the foreign ones. Specialized thermocouple cables with mineral insulation of type K, type J, type N and type P.

 

RTD cables

TE МЕ
1. Conductor - multicore silver-plated copper
2. Insulation - PFA teflon
3. Shield - tinned copper braid
4. Sheath - PFA teflon
Number of conductors: 2, 3
Conductor's section: 0,22 mm2
Operating temperature: -196...250°С
Outside diameter: 3,9/4,2 mm
1. Conductor multicore silver-plated copper
2. Insulation - PFA teflon
3. Shield tinned copper braid
Number of conductors: 2, 3, 4
Conductor's section: 0,15 or 0,22 mm2
Operating temperature: -100...250°С
Outside diameter: 2,4/2,6/2,8 mm
RS RE
1. Conductor multicore silver-plated copper
2. Insulation - PFA teflon
3. Sheath - high temperature silicone
Number of conductors: 2, 3, 4
Conductor's section: 0,15 or 0,22 mm2
Operating temperature: -70...250°С
Outside diameter: 3,0/3,2/3,8 mm
1. Conductor multicore silver-plated copper 
2. Insulation - PFA teflon
3. Shield - tinned copper braid
4. Sheath - high temperature silicone
Number of conductors: 2, 3, 4
Conductor's section: 0,15 or 0,22 mm2
Operating temperature: -70...250°С
Outside diameter: 3,9/4,2/4,5 mm
VV VE
1. Conductor multicore nickel
2. Insulation - high temperature fiberglass
3. Sheath high temperature fiberglass
Number of conductors: 3
Conductor's section: 0,50 mm2
Operating temperature: -50...400°С
Outside diameter: 3,2 mm
1. Conductor - multicore nickel
2. Insulation high temperature fiberglass
3. Sheath high temperature fiberglass
4. Shield - tinned copper braid

Number of conductors: 3
Conductor's section: 0,50 mm2
Operating temperature: -50...400°С
Outside diameter: 4,0 mm
PR OLF
1. Conductor - multicore tinned copper
2. Insulation - PVC
3. Shield - tinned copper braid
4. Sheath - PVC
Number of conductors: 4
Conductor's section: 0,25 mm2
Operating temperature: -40...100°С
Outside diameter: 4,3/4,5/4,9 mm
1. Conductor multicore tinned copper
2. Insulation - PVC
3. Sheath - polyurethane (PUR)
Number of conductors: 2, 3, 4
Conductor's section: 0,50 or 0,75 mm2
Operating temperature: -40...85°С
Outside diameter: 4,8/5,1 or 5,4/5,7 mm


 

Thermocouple cables

РС ТТ
1. Conductor - multicore thermocouple
2. Insulation - PFA teflon
3. Sheath - high temperature silicone
Type: К, L, J
Conductor's section: 0,15 or 0,22 mm2
Operating temperature: -70...250°С
Outside diameter: 2,9/3,5 mm
1. Conductor single core thermocouple
2. Insulation - PFA teflon
3. Sheath PFA teflon
Type: K, T
Conductor's diameter: 0,50 mm
Operating temperature: -196...250°С
Outside diameter (dimensions): 1,5х2,5 mm
VV VE
1. Conductor multicore thermocouple
2. Insulation high temperature fiberglass
3. Sheath high temperature fiberglass
Type: K, L, J
Conductor's section: 0,22 mm2
Operating temperature: -50...400°С
Outside diameter: 1,5x2,6 mm
1. Conductor multicore thermocouple
2. Insulation - high temperature fiberglass
3. Sheath high temperature fiberglass
4. Shield - stainless braid
Type: K, L, J
Conductor's section: 0,22 mm2
Operating temperature: -50...400°С
Outside diameter: 2,4x3,3 mm
RE
1. Conductor multicore thermocouple
2. Insulation - PFA teflon
3. Shield - tinned copper braid
4. Sheath - high temperature silicone
Type: K, L, J, N
Conductor's section: 0,22 mm2
Operating temperature: -70...250°С
Outside diameter: 3,9 mm

MI cables

TS MI cable Type K, type N MI cable
1. Conductor - copper or nickel
2.
Insulation - periclase (MgO)
3. Sheath - stainless steel 316S/321S
Number of conductors: 3, 4
Conductor's / cable's diameter: 
0,6 / 3,0 mm, 0,8 / 4,5 mm, 1,0 / 6,0 mm
Operating temperature: -196...800°С
1. Conductor - thermocouple
2. Insulation - periclase (MgO)
3. Sheath -
stainless steel 310S/316S/321S/INC/NIC
Type: K, N
Number of conductors: 1, 2
Operating temperature: -40...800°С (316S/321S), -40...1050°С (310S), -40...1150°С (INC), -40...1200°С (NIC)
Conductor's / cable's diameter: 0,6 / 3,0 mm, 0,8 / 4,5 mm, 1,0 / 6,0 mm

Application Form to order the product

Data Sheet