1-11 Model
One of the most widespread design of temperature probes. It consists of a free hex fitting and a cable. It applies to measure temperature of liquid, gas-like and air environments. It may be supplied with a threaded boss. The 4-20 mA or RS485 transducer (T-bus/ModBus protocol) can be ordered separately in Z67 enclosure with a cable gland and connect it to the probe cable.
The silicone heat shrink tube is used to avoid kinking a cable, when it's up to 250°С. And the protective spring is used, when it's over 250°С.
1-11 model can be apply as an explosion-proof temperature probe (explosion proof type - intrinsically safe electrical circuit "i"). It provides with the RE shielded cable only.
Technical specifications
Type and Nominal Resistance | Cu50 (ex-USSR), Cu100 (ex-USSR) Pt50 (ex-USSR), Pt100 (ex-USSR), Pt1000 10kNTC DS18B20 Type К Type L (ex- USSR) Type J |
Number of sensors | 1 |
Accuracy | Class В (Cu50, Cu100) Classes АА, А, В (Pt50, Pt100, Pt1000) 1% (10kNTC) 0,5°C (DS18B20) 1, 2 (K, J) 2 (L) |
RTD wire connection | 2, 3, 4 wired |
Junction type of thermocouples | Ungrounded |
Process connection size | M12x1,5 (by default) G1/4 (on order) |
Cable | RE |
Sheath material | AISI 321 |
Process temperature range, °С | -50...150 (Cu50, Cu100) -100...250, -40....100, -50...250, -50...350 (Pt50, Pt100, Pt1000) -40...120, -20...200 (10kNTC) -30...100 (DS18B20) -40...250, -40...400 (type K, J, L) |
Thermal inertia, sec | 11...13 |
Pressure, MPa | 3.0 |
Explosion-proof labelling | II 1G Ex ia IIC T6...T1 Ga |
Dimensions
Length of the immersion part, L, mm | 32, 40, 60, 80, 100, 120, 160, 200, 250, 320, 400, 500 |
Length of the remote part, mm* | 57 |
Diameter of the immersion part, mm | Ø4, Ø5, Ø6 |
* - distance between the bearing area and the industrial head
Application Form to order the product