The thermocouple model is made of the MI cable and the standard thermocouple connector. It applies to measure temperature of gas-like and air environments.

 

 

It may be bent in any direction

NOTE! Temperature near the standard connector must stay up to 200°С, near the high temperature connector - up to 350°С.

 

Technical specifications

Type and Nominal Resistance Type К
Type N
Accuracy 1, 2
Junction type Ungrounded
MI cable Stainless steel AISI 321 Ø3 mm,
stainless steel AISI 321 Ø6 mm,
stainless steel 310 Ø6 mm, 
nickel alloy Inconel 600 (INC) Ø4.5 mm,
nickel alloy Inconel 600 (INC) Ø6 mm,
nickel-chromium alloy Nicrobel (NIC) Ø6 mm
Connector Standard
Connector material Polyamide (up to 220°С)
Process temperature range, °С 0...800 (type K AISI 321)   
0...1050 (type K steel 310) 
0...1100 (type K INC)
0...1150 (type N INC)
0...1200 (type N NIC)
Thermal inertia, sec 45

Dimensions

Length of the immersion part, L, mm 250, 320, 400, 500, 630, 800, 1000, 1250, 1500, 2000... up to 20 000
Diameter of the immersion part, mm Ø3, Ø4.5, Ø6
Application Form to order the product