1-26 Model
The thermocouple model is made of the MI cable and the output thermocouple cable. It applies to measure various high temperature environments. It's recommended to order the 4-20 mA / RS485 transducer (T-bus/ModBus protocol) in the remote Z67 enclosure with a cable gland and connect it by the compensating cable to avoid overheating.

It may be bent in any direction
Technical specifications
| Type and Nominal Resistance | Type К Type N |
| Accuracy | 1, 2 |
| Junction type | Ungrounded |
| MI cable | Stainless steel AISI 321 Ø3 mm, stainless steel AISI 321 Ø6 mm, stainless steel 310 Ø6 mm, nickel alloy Inconel 600 (INC) Ø4.5 mm, nickel alloy Inconel 600 (INC) Ø6 mm, nickel-chromium alloy Nicrobel (NIC) Ø6 mm |
| Process temperature range, °С | 0...800 (type K AISI 321) 0...1050 (type K steel 310) 0...1100 (type K INC) 0...1150 (type N INC) 0...1200 (type N NIC) |
| Thermal inertia, sec | 45 |
Dimensions
| Length of the immersion part, L, mm | 250, 320, 400, 500, 630, 800, 1000, 1250, 1500, 2000... up to 20 000 |